1. Introduction
T021 catalyst is used widely to treat emission from furnace like fireplace, stove, oven etc, also for petro gas, inert
gas, oxygen and etc, to treat incompletely-burnt CO. Before using, T021 catalyst should be heated up to 180~200℃ by fresh air, in order to active its performance.
The best operating temperature: 250 centigrade, after light-off, shut down automatically compensate for heating.
2. Technology Properties
Appearance: Light brown honeycomb
Space velocity; 1×103 h-1
Light-off temperature: 150 centigrade;
Operating temperature: 300 centigrade;
CO removal ratio; 98﹪
Service life; 2 years
CO outlet content: 5ppm
Bulk density: 0.68±0.05g/mL
Crushing strength &; 14 MPa
Loading Height/diameter ratio: 4:1